| Specifications |
forty point six two | 40.xx. six | forty point one one | |
| Contact specifications | ||||
| Contact configuration | 1 CO (DPDT) | See relay forty point three one forty point five one forty point five two forty point six one Page 4 |
1 CO (SPDT) | |
| Rated current / maximum peak current a | 10/20 | 10/20 | ||
| Rated voltage / maximum switching voltage V AC | 250/400 | 250/400 | ||
| Rated load AC1 VA | two thousand and five hundred | two thousand and five hundred | ||
| Rated load ac15 (230 V AC) VA | seven hundred and fifty | five hundred | ||
| Single phase motor rating (230 V AC) kw | zero point three seven | zero point three seven | ||
| Breaking capacity dc1:30/110/220 V A | 10/0.6/0.25 | 10/0.3/0.12 | ||
| Minimum switching load MW (v/ma) | 300 (5/5) | 300 (5/5) | ||
| Standard contact material | AgNi | AgCdO | ||
| Coil specification | ||||
| Nominal voltage (UN) | V AC(50/60 Hz) | 6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 | 5 - 6 - 12 - 24 - 48 - 110 | — |
| V DC | 5 - 6 - 7 - 9 - 12 - 14 - 18 - 21 - 24 - 28 - 48 - 60 - 110 - 125 | 6 - 12 - 24 - 48 - 60 | ||
| Rated power ac/dc/ sensitive DC VA (50 Hz) /w/w | 1.2/0.65/0.5 | 1.0/1.0/— | —/—/0.5 | |
| Operating range | AC | (0.8…1.1)UN | (0.8…1.1)UN | — |
| Dc/ sensitive DC | (0.73…1.5)UN / (0.73..1.5) UN | (0.8…1.1)UN / — | —/(0.73…1.75)UN | |
| Holding voltage ac/dc | 0.8/0.4 UN | — | —/0.4 UN | |
| Required voltage ac/dc | 0.2/0.1 UN | — | —/0.1 UN | |